openapi: 3.1.1 info: title: EnergyResourceInverter version: 1.0.0 description: | Typed attribute schema for grid-connected power-electronics inverter energy resources (type = INVERTER). An INVERTER resource is a grid-connected power-electronics converter without a dedicated fuel source. It captures reactive-power and frequency-support capabilities per IEEE 1547-2018 and SunSpec DER Models 702–714. Typical use cases: - Standalone battery inverters - Virtual power plant (VPP) aggregation points - Grid-forming inverters for microgrid islanding - Reactive power compensation (STATCOM-like) CIM alignment: PowerElectronicsConnection (IEC 61970-302). Common attributes (make, model, ratedPowerKw, maxExportKw, maxImportKw, telemetryProvider, commissioningDate, location) are inherited from EnergyResourceCommon/v1.0 via allOf. components: schemas: EnergyResourceInverter: description: > A grid-connected power-electronics inverter energy resource. Captures IEEE 1547-2018 ride-through categories, operating mode, and reactive / frequency-support capabilities. CIM: PowerElectronicsConnection (IEC 61970-302). x-tags: - energy-resource - inverter - energy - deg x-jsonld: "@context": ./context.jsonld "@type": EnergyResourceInverter allOf: - $ref: "https://schema.nfh.global/EnergyResourceCommon/v1.0#/components/schemas/EnergyResourceCommon" - type: object required: [id, type] properties: type: type: string const: "INVERTER" description: > Asset-class discriminator. Must be "INVERTER". CIM: PowerElectronicsConnection (IEC 61970-302). x-jsonld: "@id": erDeg:resourceType attributes: $ref: "#/components/schemas/EnergyResourceInverterAttributes" EnergyResourceInverterAttributes: description: > Attributes for INVERTER resources. Common fields (make, model, ratedPowerKw, maxExportKw, maxImportKw, telemetryProvider, commissioningDate, location) are inherited from EnergyResourceCommonAttributes via allOf. Only IEEE 1547-2018 / SunSpec DER Model inverter-specific fields are defined here. x-jsonld: "@id": erDeg:attributes allOf: - $ref: "https://schema.nfh.global/EnergyResourceCommon/v1.0#/components/schemas/EnergyResourceCommonAttributes" - type: object additionalProperties: true properties: # ── Inverter-specific attributes (IEEE 1547 / SunSpec) ──────────── ratedApparentPowerKva: type: number minimum: 0 description: > Rated apparent power in kVA. SunSpec Model 702 maxVA. CIM: PowerElectronicsConnection.ratedS. x-jsonld: "@id": erDeg:ratedApparentPowerKva maxReactivePowerKvar: type: number minimum: 0 description: > Maximum reactive power injection (leading / over-excited), kVAr. SunSpec Model 702 maxVar. CIM: PowerElectronicsConnection.maxQ. x-jsonld: "@id": erDeg:maxReactivePowerKvar minReactivePowerKvar: type: number description: > Maximum reactive power absorption (lagging / under-excited), kVAr. Usually expressed as a negative value (e.g. -4 for 4 kVAr absorption). SunSpec Model 702 maxVarNeg. CIM: PowerElectronicsConnection.minQ. x-jsonld: "@id": erDeg:minReactivePowerKvar rideThroughCategory: type: string enum: [CategoryI, CategoryII, CategoryIII] description: > IEEE 1547-2018 abnormal operating performance category. Defines voltage and frequency ride-through requirements. CategoryI: basic — suitable for small DER with low grid impact. CategoryII: enhanced — for distribution-connected DER where ride-through improves system reliability. CategoryIII: advanced — for large or transmission-connected DER where grid support during disturbances is critical. x-jsonld: "@id": erDeg:rideThroughCategory operatingMode: type: string enum: [GridFollowing, GridForming, Standby] description: > Inverter grid-interaction mode. GridFollowing: synchronises phase angle and frequency to existing grid voltage/frequency reference (PLL-based; typical for DER). GridForming: establishes its own V/f reference without external synchronisation — enables microgrid islanding and black-start. Standby: inverter energised but not injecting real power. CIM: PowerElectronicsConnection.inverterMode. x-jsonld: "@id": erDeg:operatingMode voltVarEnabled: type: boolean description: > Volt-VAr curve active — autonomous reactive power response as a function of terminal voltage. IEEE 2030.5 opModVoltVar / SunSpec Model 705 (Volt-VAr). x-jsonld: "@id": erDeg:voltVarEnabled freqDroopEnabled: type: boolean description: > Frequency-Watt droop active — active power output reduced proportionally to over-frequency deviation. SunSpec Model 711 (Freq-Watt) / IEEE 1547-2018 Frequency-Watt. x-jsonld: "@id": erDeg:freqDroopEnabled enterServiceRampTimeSec: type: number minimum: 0 description: > Time in seconds to ramp from 0 to rated power after reconnection to the grid. Controls inrush on re-energisation. SunSpec Model 703 ESRmpTms. x-jsonld: "@id": erDeg:enterServiceRampTimeSec